Tesira TEC-1s

Biamp Tesira TEC-1s PoE Ethernet Control Panel

Platforms
TAA Compliant
WhatsApp
Priceon request
QuotationWithin 1 working day
DeliveryConfirmed with your quote, based on stock
PDFDownload datasheet (biamp_system_design_guide_corporate_campus_aug25.pdf)
Overview

The Biamp Tesira TEC-1s is a surface-mount Ethernet control device for Tesira systems. It runs on PoE, so one CAT-5/6/7 cable carries both power and control, with no local power supply needed. A high-contrast OLED with capacitive touch lets users adjust up to 32 programmed volumes and actions. It suits meeting rooms, boardrooms, lecture halls and hotel venues across Qatar that need simple room control. Request a quote.

How the TEC-1s is programmed for each room

The TEC-1s is an Ethernet control device built for Tesira systems. It gives end users a simple, direct interface, while the integrator sets up what each panel does. Every unit is configured in the Tesira system design software, so the same hardware can serve a boardroom, a lecture theatre or a restaurant zone depending on the functions assigned to it.

Each panel can be assigned up to 32 selectable functions. A volume might cover a single input, an output, a matrix crosspoint or a group of levels. An action might be a preset, a source selection, a mute, ducking or the combining of rooms. Because the functions are defined in software, the panel can be matched to the layout of the room rather than the other way round.

Power and cabling over one Ethernet run

The TEC-1s runs on PoE under IEEE 802.3at Class 1, drawing 4W, so it needs no separate power adaptor or local supply at the wall position. It connects over standard CAT-5, CAT-6 or CAT-7 unshielded twisted pair cabling, terminated with RJ-45 or insulation displacement connectors. A 100 m (330 feet) run is supported, and longer distances can be reached by adding standard PoE network equipment such as switches, routers, hubs or media converters.

Display and touch built for busy rooms

The high-contrast OLED display has a wide viewing angle, so people at the far side of a table can read it. Brightness can be set to suit ambient light, and the screen dims automatically when the panel is idle. The capacitive touch surface has no protruding or moving parts, which supports long-term reliability and makes the panel simpler to clean in schools and hospitals.

Where it fits in Qatar

  • Boardroom in West Bay: one panel switches between conferencing and video playback presets.
  • Hotel ballroom in Lusail: moveable partitions are linked to remote room combining, with volume functions grouped automatically.
  • Restaurant or bar in The Pearl: each zone gets its own source selection and room volume control.

Planning the install and requesting a quote

Check that each panel position has a PoE-capable switch port within reach of the 100 m limit, and that the Tesira design includes the functions the panel must control, since the TEC-1s only exposes what is programmed. The unit measures 130 mm high, 120 mm wide and 32 mm deep, weighs 0.2 kg and is designed for surface mounting. No operating temperature range is given in the manufacturer data, so for panels near windows or in spaces outside air conditioning, confirm conditions with the SmartRooms Qatar team first. The unit carries a 5-year warranty, is TAA compliant and is marked RoHS, CE and FCC. Free site surveys are available, and government buyers can order by LPO or through Monaqasat tenders. Request a quote with your room list and Tesira layout, and we will usually respond within one working day.

Highlights

  • Powered over Ethernet, IEEE 802.3at Class 1, 4W
  • Up to 32 programmable volumes and actions
  • High-contrast OLED with wide viewing angle
  • Capacitive touch with no protruding or moving parts
  • 100 m (330 ft) Ethernet reach, extendable with PoE equipment
  • 5-year warranty; TAA compliant; RoHS, CE, FCC

Room fit

Tell us the room size and platform (Teams, Zoom or BYOD) and we confirm the right combination with your quotation.

Estimated timeline

Quotation within 1 working day · delivery timing depends on stock availability, and we confirm it with your quotation.

Specifications

10 specifications · Source: manufacturer · checked Oct 2026
GENERAL5
Height
5.1 inches (130mm)
Width
4.7 inches (120mm)
Depth
1.25 inches (32mm)
Weight
0.5 lb (0.2kg)
Included Accessories
TEC-1s is designed to mount to a surface and includes a molded rear chassis with accommodation for cabling and for physically attaching the entire assembly to a surface
POWER1
Power
PoE (IEEE 802.3at Class 1, 4W)
CONTROLS & INDICATORS1
Control
Control Cable Requirements: Unshielded twisted pair (UTP) wiring, 100BaseT interface (CAT-5/6/7 Ethernet cable) using either RJ-45 or Insulation Displacement Connector (IDC) Control Cable Length: 330' (100m) Ethernet cable length can be extended with standard PoE network technology Control Wiring: Topology Standard Ethernet network wiring Control Programming: Each control configured for specific operation by the system design software Applications: Source Selection: Selection and level control of input sources for background music, such as CD player and auxiliary devices Paging/Music Zone: pag
CERTIFIED SOLUTIONS2
TAA Compliant
TAA Compliant
Certified Solutions
TAA Compliant
COMPLIANCE1
Certifications
RoHS Directive; CE; FCC

Downloads

8 files from the manufacturer

Questions about Tesira TEC-1s

What is the Biamp Tesira TEC-1s used for?
The TEC-1s is an Ethernet control panel for Tesira systems. Users adjust volumes and trigger presets, source selections, mutes or room combining from the panel, while the integrator defines those functions in the Tesira system design software. It suits meeting rooms, boardrooms, lecture halls and multi-zone venues where a single room needs simple, fixed controls rather than a full control system. Quote requests usually start with a room list and a sketch of the Tesira layout.
Does the TEC-1s need a separate power supply?
No. The TEC-1s is powered over Ethernet under IEEE 802.3at Class 1 and draws 4W, so the same CAT-5, CAT-6 or CAT-7 cable carries power and control. Confirm that the switch port feeding each panel supplies PoE before installation, because a non-PoE port will not power the unit. This removes the need for a local power point at the wall position in boardrooms and lecture halls.
How far can the TEC-1s be from the Tesira system?
Each run supports 100 m (330 feet) of standard Ethernet cable. For longer distances, the cable can be extended using standard PoE network equipment such as switches, routers, hubs and media converters. In a large multi-storey building, such as a university block in Education City, plan switch locations along the cable route and measure the routes during a free site survey before ordering.
What can the TEC-1s control?
The unit can adjust or start up to 32 selectable functions. A function can be a volume for an input, output, matrix crosspoint or group of levels, or an action such as a preset, source selection, mute, ducking or room combining. Which 32 are shown is set in the Tesira system design software during programming, so the panel only exposes what the integrator has defined for that room.
Is the TEC-1s suitable for a boardroom in West Bay?
Yes, for a boardroom where the presenter needs to switch between conferencing and video playback without operating the whole AV system. The TEC-1s can be programmed with individual source volume control and room mode presets, such as conferencing or video playback. Its OLED display has a wide viewing angle, and its brightness can be matched to the room lighting.
How does the TEC-1s work in a hotel ballroom in Lusail?
A ballroom with moveable partitions benefits from room combining. The TEC-1s can be programmed to select room combinations based on preset configurations or moveable partitions, with volume functions combining automatically. A wall panel at each entrance can therefore control the active room layout. Confirm the partition configurations and the number of panel positions with the SmartRooms Qatar team during a site survey before ordering.
Can the TEC-1s control background music in a restaurant or bar?
Yes. The manufacturer lists restaurant and bar music as an application, where the panel selects sources and controls room volume independently per zone, or from one central control. For a restaurant in The Pearl with several dining areas, each zone can have its own panel. The panel works within the complete Tesira design and does not replace the audio system itself.
How readable is the display in bright or dim rooms?
The high-contrast OLED has a wide viewing angle, so users seated away from the panel can read it. Brightness can be adjusted to suit ambient light, and the display dims automatically when not in use. These settings matter in a lecture hall where lights are lowered for projection, and in a bright atrium where glare can wash out a screen.
Is the touch surface prone to wear like mechanical buttons?
The TEC-1s uses capacitive touch, which removes protruding and moving parts. The manufacturer states that this increases product reliability and longevity and simplifies cleaning. In schools, hospitals and busy meeting rooms, a flat touch surface is easier to wipe down than a panel with mechanical switches. The manufacturer provides a 5-year warranty on the TEC-1s.
What are the size and weight of the TEC-1s, and how is it mounted?
The unit measures 130 mm high, 120 mm wide and 32 mm deep, and weighs 0.2 kg. It is designed to mount to a surface, with a molded rear chassis that accommodates the cabling and attaches the assembly to the surface. Check the planned position and cable route during a free site survey before fixing the unit in place.
Is the TEC-1s compliant for public sector purchases?
The TEC-1s is TAA compliant and listed for RoHS, CE and FCC. TAA compliance matters where Trade Agreements Act rules apply to a specification. Government ministries and public bodies in Qatar can request a quote and order by purchase order (LPO), or through a Monaqasat tender, with payment by bank transfer, cheque or purchase order.
Can a school order several TEC-1s panels at once?
Yes. Send SmartRooms Qatar the number of TEC-1s panels, the rooms they will serve and the Tesira system layout, and we will usually provide a quotation within one working day. Schools ordering several units for classrooms or halls can raise a purchase order. Lead times are estimates and are confirmed with the quotation.

Similar models

Biamp Evoko Kleeo Power Supply Biamp Evoko Kleeo Power Supply 910-00800 for Kleeo Desk Manager
Control & scheduling
Biamp Evoko Liso Power Supply Biamp Evoko Liso Power Supply 910-11936 for Liso Room Manager
Control & scheduling
Email Call